Skip to Main Content

General Pump 100825 GP Adjustable Brass Downstream Chemical Injector, 3-5 GPM

Brand:
Mfr. Model #:
100825
KR Part #:
GPP100825
Weight:
0.30 lbs
GTIN:
682491029830
Out of Stock - Pre-Order Now
MSRP
$39.43
Now Only!
$14.92
starstarstarstarstar (0)

This downstream pressure washer injector features an adjustable 1/4-inch hose barb. It is made of brass for durability and corrosion resistance. General Pump engineered downstream injector to handle a flow rate of 3-5 GPM and a maximum pressure of 4500 PSI. It can also be used in car washes.

 
 

Technical Specifications

Max PSI: 4500
Max Temperature: 190 degrees F
Min GPM: 3
Max GPM: 5
Inlet Port: 3/8 inch
Outlet Port: 3/8 inch

Product Description

3-5 GPM Downstream Chemical Injector

General Pump 100825 is a downstream chemical injector for pressure washers and car washes with a 1/4-inch hose barb that is adjustable. It handles a flow rate of 3-5 GPM and a maximum pressure of 4500 PSI. This adjustable downstream injector is made with brass for durability and corrosion resistance.

Specifications:

  • Manufacturer Product Number: 100825
  • Flow Rate: 3.0 to 5.0 GPM
  • Max PSI: 4500
  • Max Temperature: 190°F
  • Inlet Port: 3/8" NPT-M
  • Outlet Port: 3/8" NPT-M
  • Hose Barb: 1/4", adjustable
  • Material: Brass
  • O-Ring: Viton

Application:

  • Car Washes
  • Pressure Washing

Installation:

  • Install valve with direction arrow pointing downstream. For proper operation, a control device such as a dual lance wand, quick couple nozzles, or an adjustable nozzle holder must be used to lower the system pressure at the nozzle. Warning: Under no circumstances should the system pressure exceed the maximum rated pressure of any component.

Troubleshooting:

  • Injector will not draw liquid
    • Cause:
      1. Incorrect nozzle
      2. The system is not in low-pressure mode
      3. Discharge hose is too long 
      4. Chemical line is clogged
    • Solution:
      1. Check and change the nozzle
      2. Change or adjust the nozzle to put the system in low-pressure mode
      3. Reduce the length of the discharge hose or change the injector
      4. Clear chemical line of obstruction
  • Rate of draw seems too slow
    • Cause:
      1. Discharge hose is too long
      2. Air leak in chemical line
      3. Chemical is too viscous
    • Solution:
      1. Reduce the length of the discharge hose or change the injector
      2. Locate and repair the leak
      3. Reduce the chemical with water to decrease viscosity
  • Chemical injector is leaking from hose barb
    • Cause:
      1. Obstruction in hose barb check valve
      2. Damaged O-ring in check valve
    • Solution:
      1. Disassemble and remove obstruction
      2. Remove and replace O-ring
  • Excessive pressure load on pump, motor, or engine
    • Cause
      1. Clogged injector
      2. Improperly sized injector orifice
    • Solution
      1. Clear injector orifice of obstruction
      2. Change orifice

Product Reviews

0  Customer Review(s)
5 Star
0  (0%)
4 Star
0  (0%)
3 Star
0  (0%)
2 Star
0  (0%)
1 Star
0  (0%)

CID: -1 QueryString:general-pump-100825-gp-adjustable-brass-downstream-chemical-injector-3-5-gpm| Runtime:falsep-38592.aspx/p-38592.aspxen-US2https://www.highpressurepumpsandparts.com/3/16/2025searchEngineName=general-pump-100825-gp-adjustable-brass-downstream-chemical-injector-3-5-gpmcompunix.productreviews.xml.config102036516949TrueUSDTrue18.221.129.800TrueFalse6:37 AM1FalseUSDTrueen-USFalse0en-US385921FalseFalseproduct| LastCustomerReview: